Daikin error code A6

What it means

Indoor fan motor fault.

Possible causes

Fan motor failure Mechanical obstruction or seized bearings Defective motor driver section on PCB

Suggested fix

Inspect the fan assembly for mechanical issues and test motor windings and driver outputs; replace the fan motor or PCB once testing identifies the failed component.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other Daikin codes
  • A1 — Indoor PCB defect or internal failure.
  • A5 — Freeze-up protection activated for the indoor heat exchanger.
  • C4 — Faulty indoor heat exchanger temperature sensor.
  • C9 — Faulty indoor suction air (room) temperature sensor.
  • E1 — Outdoor circuit board fault.
  • E7 — Outdoor DC fan motor fault.
  • F6 — High pressure control activated in cooling mode.
  • U0 — Refrigerant shortage or undercharge detected.
  • U2 — Power supply voltage drop or main circuit overvoltage.
  • U4 — Transmission failure between indoor and outdoor units.