Gree error code F4

What it means

Outdoor coil temperature sensor fault.

Possible causes

Coil thermistor open or short Sensor mounting loose or corroded Harness insulation damage

Suggested fix

Check sensor contact with the coil and wiring integrity, then verify resistance; repair mounting or harness and replace the thermistor if its readings are not within the expected range.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other Gree codes
  • C5 — Configuration jumper or PCB setup error.
  • E1 — High pressure protection in the refrigeration circuit.
  • E3 — Low pressure protection.
  • E5 — Overcurrent protection on compressor or main circuit.
  • E7 — Mode conflict between indoor and outdoor units.
  • F1 — Indoor ambient (room) sensor fault.
  • F2 — Indoor evaporator temperature sensor fault.
  • F3 — Outdoor ambient temperature sensor fault.
  • F5 — Compressor discharge temperature sensor fault.
  • H1 — Defrost mode status indication (not a fault).