Samsung error code E123

What it means

Indoor EVAP OUT temperature sensor error (short or open).

Possible causes

Evaporator outlet thermistor open or short Sensor wiring damaged Connector not seated on PCB

Suggested fix

Inspect the EVAP OUT sensor wiring and connector and verify resistance against specification; replace the sensor or PCB channel as required after confirming the measurements.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other Samsung codes
  • C5 — Malfunction protection of jumper cap (applies to the AR09-AR24TSHGAWKN midwall range).
  • E1 — High-pressure protection of the system (applies to the AR09-AR24TSHGAWKN midwall range).
  • E101 — Indoor unit communication error.
  • E102 — Communication error between indoor and outdoor units.
  • E108 — Duplicate device address error on the communication network.
  • E121 — Indoor room temperature sensor fault.
  • E122 — Indoor EVAP IN temperature sensor error (short or open).
  • E154 — Indoor fan motor or fan system error.
  • E163 — EEPROM option data error on the indoor PCB.
  • E2 — Anti-freezing protection (applies to the AR09-AR24TSHGAWKN midwall range).

Need the unit's specs?

Browse Samsung models