Sinclair error code F5

What it means

Discharge line temperature sensor fault.

Possible causes

Thermistor failure Harness burnt or damaged by high discharge temperature Connector loose at PCB

Suggested fix

Inspect the discharge sensor and associated wiring for thermal and mechanical damage and test resistance; reroute and insulate wiring appropriately and fit a new sensor where required before clearing the fault.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other Sinclair codes
  • E1 — High pressure protection or system high-pressure fault.
  • E2 — System low-pressure fault.
  • E3 — System low-pressure protection (severe or repeated low-pressure event).
  • E5 — Current protection on compressor or fan circuit.
  • E6 — Communication error between indoor and outdoor units.
  • F1 — Indoor air (room) temperature sensor fault.
  • F2 — Indoor coil temperature sensor fault.
  • F3 — Outdoor ambient temperature sensor fault.
  • F4 — Outdoor coil temperature sensor fault.

Need the unit's specs?

Browse Sinclair models