Alliance error code E1

What it means

Communication error between indoor and outdoor units (Midea-platform logic).

Possible causes

Interconnecting cable fault Incorrect wiring order at terminals Failed communication interface on PCB

Suggested fix

Confirm correct wiring and polarity of the interconnecting cable and ensure outdoor power is present; if wiring and supply are sound, perform board communication tests and replace the faulty PCB.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other Alliance codes
  • E2 — Indoor temperature or evaporator sensor error.
  • E3 — Refrigerant leak or low capacity protection.
  • E4 — Compressor or discharge temperature error.
  • E5 — Fan motor fault.
  • EC — Refrigerant leakage alarm.
  • F0 — Low refrigerant protection.
  • F1 — Indoor ambient temperature sensor fault.
  • F2 — Indoor evaporator temperature sensor fault.
  • F3 — Outdoor ambient temperature sensor fault.

Need the unit's specs?

Browse Alliance models