Alliance air conditioner error codes

Displayed on the indoor unit or remote when a fault is detected. Always isolate power before inspecting a unit — repairs belong to a qualified technician.

CodeMeaningApplies to
E0 Meaning depends on unit type — Inverter midwall: EEPROM error; Inverter under-ceiling/cassette/ducted: communication between indoor and outdoor units; Package unit: phase rotation / phase missing; Integrated water heater: error of sensor T5U. All models Details
E1 Meaning depends on unit type — Vertu fixed-speed midwall / Fixed-speed under-ceiling/cassette/ducted: EEPROM error; Atlantic midwall: outdoor tube sensor fault; Inverter midwall: indoor-outdoor communication error; Inverter under-ceiling/cassette/ducted / Pool heater / Commercial water heater: phase rotation / phase missing; Package unit: outdoor coil sensor, system A; Portable: room temperature sensor error; Water heater (retrofit): phase reversal / phase missing error; Integrated water heater: error of sensor T5L. All models Details
E2 Meaning depends on unit type — Vertu fixed-speed midwall / Inverter midwall / Fixed-speed under-ceiling/cassette/ducted: zero-crossing detection error; Atlantic midwall: room temperature sensor open or short circuit; Inverter under-ceiling/cassette/ducted: communication error between indoor unit and master unit; MAC cassette: room temperature sensor failure; Package unit: outdoor coil sensor, system B; Portable: evaporator temperature sensor error; Water heater (retrofit): communication error between unit and wired control, or sensor damaged; Pool heater: outdoor unit and wire controller communication error; Integrated water heater: tank and wired controller communication error; Commercial water heater: communication failure between wired remote and main unit. All models Details
E3 Meaning depends on unit type — Vertu fixed-speed midwall / Inverter midwall / Fixed-speed under-ceiling/cassette/ducted: indoor fan error; Atlantic midwall: indoor coil sensor open or short circuit; MAC cassette: coil temperature sensor failure; Portable: condenser temperature sensor error; Water heater (retrofit) / Pool heater: outlet water temperature sensor error; Commercial water heater: outlet water temperature sensor failure. All models Details
E4 Meaning depends on unit type — Inverter midwall: indoor room temperature sensor open or short circuit; Inverter under-ceiling/cassette/ducted: outdoor temperature sensor error; MAC cassette: condenser sensor failure; Water heater (retrofit): water temperature sensor failure in the water tank; Pool heater: inlet water temperature sensor error; Integrated water heater: condenser pipe temperature sensor error; Commercial water heater: water temperature sensor in the water tank failure. All models Details
E5 Meaning depends on unit type — Vertu fixed-speed midwall / Fixed-speed under-ceiling/cassette/ducted: room temperature sensor open or short circuit; Atlantic midwall: indoor fan fault; Inverter midwall: indoor coil sensor open or short circuit; Inverter under-ceiling/cassette/ducted: compressor discharge temperature sensor error; MAC cassette: water pump temperature sensor error; Package unit: indoor coil sensor, system A; Water heater (retrofit): condenser temperature sensor error; Pool heater: evaporator pipe temperature sensor error; Integrated water heater: outdoor ambient temperature sensor error; Commercial water heater: condenser temperature sensor failure. All models Details
E6 Meaning depends on unit type — Vertu fixed-speed midwall / Fixed-speed under-ceiling/cassette/ducted: indoor coil sensor open or short circuit; Atlantic midwall: EEPROM error; MAC cassette: outdoor malfunction; Package unit: indoor coil sensor, system B; Water heater (retrofit): outdoor ambient temperature sensor error; Integrated water heater: sensor Tp error; Commercial water heater: outdoor ambient temperature sensor failure. All models Details
E7 Meaning depends on unit type — Atlantic midwall: external feedback fault (check interconnecting wiring); MAC cassette: EEPROM malfunction; Water heater (retrofit): sensor failure at water pump outlet; Pool heater: ambient temperature sensor error; Commercial water heater: electric heating pipe temperature sensor failure. All models Details
E8 Meaning depends on unit type — Atlantic midwall: overheat detection / defrosting; Inverter under-ceiling/cassette/ducted: outdoor unit address error; MAC cassette: water-level alarm; Integrated water heater: electric leakage protection. All models Details
E9 Meaning depends on unit type — Inverter under-ceiling/cassette/ducted: power voltage error; Package unit: indoor temperature sensor error; Water heater (retrofit): T8 temperature sensor error; Pool heater: water flow switch error. All models Details
EA Outdoor ambient sensor error (Package unit units). All models Details
EB Meaning depends on unit type — Package unit: wire controller output error; Commercial water heater: exhaust temperature sensor error (TP). All models Details
EC Meaning depends on unit type — Vertu fixed-speed midwall / Inverter midwall / Fixed-speed under-ceiling/cassette/ducted: refrigerant leak detected; Commercial water heater: water inlet temperature sensor error. All models Details
ED Sensor failure at double-pipe refrigerant outlet (Water heater (retrofit) units). All models Details
EE Discharge pipe temperature sensor error (Pool heater units). All models Details
F0 Low refrigerant protection. All models Details
F1 Outdoor temperature sensor open or short circuit (Inverter midwall units). All models Details
F2 Condenser coil sensor open or short circuit (Inverter midwall units). All models Details
F3 Compressor discharge sensor open or short circuit (Inverter midwall units). All models Details
F4 Outdoor EEPROM error (Inverter midwall units). All models Details
FT Full tray or full tank (Portable units). All models Details
H0 Communication malfunction between IR341 and 780034 chips (Inverter under-ceiling/cassette/ducted units). All models Details
H1 Communication between 0537/9177 and 780034 chips (Inverter under-ceiling/cassette/ducted units). All models Details
H2 Quantity of outdoor units decreased (Inverter under-ceiling/cassette/ducted units). All models Details
H3 Quantity of outdoor units increased (Inverter under-ceiling/cassette/ducted units). All models Details
H4 P6 protection detected 3 times (Inverter under-ceiling/cassette/ducted units). All models Details
H5 P2 detected 3 times in 30 minutes (Inverter under-ceiling/cassette/ducted units). All models Details
H6 P4 detected 3 times in 100 minutes (Inverter under-ceiling/cassette/ducted units). All models Details
H7 Indoor unit decrease error (Inverter under-ceiling/cassette/ducted units). All models Details
H8 Discharge pressure sensor error (Inverter under-ceiling/cassette/ducted units). All models Details
H9 P9 detected 3 times in 30 minutes (Inverter under-ceiling/cassette/ducted units). All models Details
HO Indoor and outdoor units unmatched (Water heater (retrofit) units). All models Details
HP High-pressure alarm (Portable units). All models Details
L0 DC inverter module protection (Inverter under-ceiling/cassette/ducted units). All models Details
L1 DC supply low voltage (Inverter under-ceiling/cassette/ducted units). All models Details
L2 DC supply high-voltage protection (Inverter under-ceiling/cassette/ducted units). All models Details
L4 MEC failure (Inverter under-ceiling/cassette/ducted units). All models Details
L8 Frequency protection (Inverter under-ceiling/cassette/ducted units). All models Details
L9 Frequency protection (Inverter under-ceiling/cassette/ducted units). All models Details
LA Ambient temperature is outside the 5-43 °C range (Integrated water heater units). All models Details
LT Low temperature (Portable units). All models Details
P0 Meaning depends on unit type — Inverter midwall: IPM malfunction or IGBT over-current; Inverter under-ceiling/cassette/ducted: inverter compressor top temperature protection; Package unit: overcurrent protection, system A; Pool heater: discharge pressure over-high protection; Integrated water heater: condenser pipe temperature overflow protection; Commercial water heater: system LP protection. All models Details
P1 Meaning depends on unit type — Inverter midwall: over- or under-voltage protection; Inverter under-ceiling/cassette/ducted: high-pressure protection; Package unit: overcurrent protection, system B; Portable: bottom tray is full; Water heater (retrofit): HP protection / air in system / pump not starting / no water; Pool heater: low-pressure protection; Commercial water heater: system HP protection (check circulating pump). All models Details
P2 Meaning depends on unit type — Inverter midwall: compressor top temperature protection (normally shortage of refrigerant); Inverter under-ceiling/cassette/ducted: low-pressure protection; Package unit: overcurrent protection for outdoor fan; Water heater (retrofit): system current protection; Integrated water heater: high discharge temperature; Commercial water heater: current protection, system 2. All models Details
P3 Meaning depends on unit type — Inverter under-ceiling/cassette/ducted: inverter compressor current protection; Package unit: comprehensive protection for outdoor fan; Integrated water heater: open compressor circuit protection; Commercial water heater: current protection, system 1. All models Details
P4 Meaning depends on unit type — Inverter midwall: inverter compressor drive error; Inverter under-ceiling/cassette/ducted: compressor discharge temperature protection (shortage of refrigerant); Package unit: HP/LP or discharge temperature protection, system A; Water heater (retrofit): tt HP protection; Pool heater: compressor over-current protection; Integrated water heater: compressor overcurrent protection. All models Details
P5 Meaning depends on unit type — Inverter under-ceiling/cassette/ducted: outdoor condenser high-temperature protection; Package unit: HP/LP or discharge temperature protection, system B; Water heater (retrofit): condenser HP protection. All models Details
P6 Meaning depends on unit type — Inverter under-ceiling/cassette/ducted: inverter module protection; Package unit: HP protection in T2 evaporator — stops the outdoor unit fan; Pool heater: evaporator over-temperature protection. All models Details
P7 Meaning depends on unit type — Inverter under-ceiling/cassette/ducted: current protection, fixed compressor No. 1; Package unit: HP protection in T2 evaporator — stops the outdoor unit fan and compressor. All models Details
P8 Meaning depends on unit type — Inverter under-ceiling/cassette/ducted: current protection, fixed compressor No. 2; Package unit: condenser high-temperature protection, system A; Water heater (retrofit): protection for over-temperature at condenser outlet; Integrated water heater: open upper e-heater circuit protection; Commercial water heater: protection for excessively high outlet water temperature. All models Details
P9 Meaning depends on unit type — Inverter under-ceiling/cassette/ducted: fan motor protection; Package unit: condenser high-temperature protection, system B; Water heater (retrofit): anti-freezing protection; Integrated water heater: upper e-heater overload protection. All models Details
PA Open lower e-heater circuit protection (Integrated water heater units). All models Details
PB Meaning depends on unit type — Water heater (retrofit) / Commercial water heater: anti-freezing protection; Pool heater: anti-freeze protection; Integrated water heater: lower e-heater overload protection. All models Details
PC Anti-freezing protection for evaporator, system A (Package unit units). All models Details
PD Anti-freezing protection for evaporator, system B (Package unit units). All models Details
PF Meaning depends on unit type — Package unit: defrosting; Portable: probe failure; Pool heater: discharge temperature protection (too high). All models Details