Carrier error code E2

What it means

Evaporator coil temperature sensor fault.

Possible causes

Evaporator sensor open or short Loose connector at indoor PCB Damaged sensor harness

Suggested fix

Measure sensor resistance and examine wiring and connector integrity; replace the sensor or repair harness as required and verify readings against Carrier specifications.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other Carrier codes
  • E1 — High pressure protection in the refrigeration circuit.
  • E3 — Low pressure protection.
  • E4 — Compressor discharge temperature protection.
  • E5 — Overcurrent or overload protection.
  • E6 — Communication error between indoor and outdoor units.
  • EC — Refrigerant leak detection alarm.
  • F0 — Low refrigerant protection.
  • P0 — High voltage protection.
  • P1 — Low voltage protection.
  • P4 — Fan speed fault.