LG error code CH03

What it means

Drain pump or condensate removal error.

Possible causes

Condensate pump not running Float switch stuck in high position Blocked drain line causing pan overflow

Suggested fix

Clean the drain pan and line, then test pump and float operation under water load; replace the pump or float assembly if electrical tests and functional checks confirm failure.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other LG codes
  • CH01 — Indoor air (room) temperature sensor fault.
  • CH02 — Indoor pipe (coil) temperature sensor fault.
  • CH05 — Communication fault between the indoor and outdoor unit.
  • CH09 — Indoor unit EEPROM or memory error.
  • CH10 — Indoor fan motor fault or abnormal fan operation.
  • CH21 — Outdoor DC compressor IPM (inverter power module) fault.
  • CH22 — Outdoor current transformer (CT) error.
  • CH23 — Outdoor DC compressor overcurrent protection.
  • CH61 — High temperature protection in outdoor unit (cooling) or indoor unit (heating).
  • CH67 — Outdoor fan motor fault.