LG error code CH09

What it means

Indoor unit EEPROM or memory error.

Possible causes

Corrupted indoor memory data Power interruption during EEPROM write Incompatible or incorrectly programmed replacement PCB

Suggested fix

Perform a full power reset at the isolator and, if the error recurs, replace the indoor PCB and program all required parameters following LG service documentation.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other LG codes
  • CH01 — Indoor air (room) temperature sensor fault.
  • CH02 — Indoor pipe (coil) temperature sensor fault.
  • CH03 — Drain pump or condensate removal error.
  • CH05 — Communication fault between the indoor and outdoor unit.
  • CH10 — Indoor fan motor fault or abnormal fan operation.
  • CH21 — Outdoor DC compressor IPM (inverter power module) fault.
  • CH22 — Outdoor current transformer (CT) error.
  • CH23 — Outdoor DC compressor overcurrent protection.
  • CH61 — High temperature protection in outdoor unit (cooling) or indoor unit (heating).
  • CH67 — Outdoor fan motor fault.

Need the unit's specs?

Browse LG models