TCL error code E2

What it means

Indoor evaporator temperature sensor fault.

Possible causes

Evaporator sensor open or short Connector partially inserted Sensor displaced from coil

Suggested fix

Check sensor placement and wiring and compare resistance values to the manufacturer's chart; reposition or replace the sensor and repair harness issues before returning the unit to service.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other TCL codes
  • E1 — High pressure protection.
  • E3 — Low pressure protection.
  • E4 — Compressor discharge temperature protection.
  • E5 — Overcurrent or overload protection.
  • E6 — Communication error between indoor and outdoor units.
  • EC — Refrigerant leak detection alarm.
  • P0 — High voltage protection.
  • P1 — Low voltage protection.
  • P2 — Condensate pan full or water-level protection.
  • P4 — Fan speed error or monitored speed out of range.

Need the unit's specs?

Browse TCL models