TCL error code P0

What it means

High voltage protection.

Possible causes

Supply voltage exceeding design limit Wiring errors at isolator or distribution board Surge or transient overvoltage

Suggested fix

Measure supply voltage profile, correct wiring and site power configuration and install appropriate surge protection; replace damaged inverter or protective components before re-energizing the system.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other TCL codes
  • E1 — High pressure protection.
  • E2 — Indoor evaporator temperature sensor fault.
  • E3 — Low pressure protection.
  • E4 — Compressor discharge temperature protection.
  • E5 — Overcurrent or overload protection.
  • E6 — Communication error between indoor and outdoor units.
  • EC — Refrigerant leak detection alarm.
  • P1 — Low voltage protection.
  • P2 — Condensate pan full or water-level protection.
  • P4 — Fan speed error or monitored speed out of range.

Need the unit's specs?

Browse TCL models