TCL error code P2

What it means

Condensate pan full or water-level protection.

Possible causes

Blocked drain line Float switch activated due to high water level Failure of drain pump where fitted

Suggested fix

Inspect and clear the drain line and pan and verify float switch and pump operation; replace defective water-level components to prevent overflow and nuisance trips.

Safety first. Isolate the power supply before inspecting any unit. Refrigerant-circuit and electrical repairs must be carried out by a qualified, registered technician.
Other TCL codes
  • E1 — High pressure protection.
  • E2 — Indoor evaporator temperature sensor fault.
  • E3 — Low pressure protection.
  • E4 — Compressor discharge temperature protection.
  • E5 — Overcurrent or overload protection.
  • E6 — Communication error between indoor and outdoor units.
  • EC — Refrigerant leak detection alarm.
  • P0 — High voltage protection.
  • P1 — Low voltage protection.
  • P4 — Fan speed error or monitored speed out of range.

Need the unit's specs?

Browse TCL models